S&T CABLES

Switchboard cables

PVC Twin flat-2 core

  • 10 pair-0.4/0.5/0.63mm (dia of conductor )
  • 20 pair-0.4/0.5/0.63mm (dia of conductor )
  • 50 pair-0.4/0.5/0.63mm (dia of conductor )
  • 100 pair-0.5/0.63mm (dia of conductor )
  • These cables are used for Indoor extension
  • These cables are used for indoor extension
  • TEC Spec.No: GR/WIR/06/03 of March 2002

Underground PIJF cables

Conforming to standard specifications like DOT spec. no. G/CUG -01/03 AUG 2003 , BS 3573, IEC708-1, CW 112

  • RDSO Spec. No:IRS:TC 41/97 (Amd. 2)
  • 10 pair-0.4/0.5/0.63mm (dia of conductor )
  • 20 pair-0.4/0.5/0.63mm (dia of conductor )
  • 50 pair-0.4/0.5/0.63mm (dia of conductor )
  • 100 pair-0.5/0.63mm (dia of conductor )
  • These cables are used for outdoor extension

Data Communication Cables For data communication

Two types of cable are used for LAN network:

i. UTP: Unshielded twisted pair Cat6 1000Mbps@250Mhz

ii. STP: Shielded twisted pair Cat6 1000Mbps@250Mhz

1. PVC Insulated Armoured, Unscreened Underground Power Cable IRS:S-63/2007 (with Amdt-1) & IS:1554 ( Part-1) SIQ-0701

2. PVC Insulated Railway Signalling Indoor Single Core Cable IRS:S-76/89 (Amendment-2) SIQ-0701

3. PVC Insulated Railway Signalling Indoor Multi Core Cable IRS:S-76/89 (Amendment-2) SIQ-0701

4. PVC Insulated Armoured, Aluminum Screened Underground Cable IRS:S-35/93 SIQ-0701

5. PVC Insulated Armoured, Unscreened, Underground Railway Signaling Cable IRS:S-63/2007 (with Amdt-1)

CF CT 445, NF F 55-698, IRS S 63, IRS S76, IRS TC 30, IRS SPC_TC_72, IEC 60332-1-2

These cables are used for transfer of signals in railway networks in signalling circuits to connect the signalling equipment.

Railway Cables

IRS TC 30/05, RDSO/SPN/TC/72/07, IRS S 63/2014, IRS S 76/89 IRS TC 41/97, IS: 1554(Part 1), IS: 7098 (Part 1), ETI/OHE/76(6/97), ETI/ OHE/50(6/97).

Instrumentation cables

IEC 60189,VDE 0207, EIL-6-52-46, EIL — 6-51-52, BS:5308 Part 1 & 2, BSC 143-0.75 (24/0.2 min) OAS, IEC 60092-375, 376, BS EN 50288 PART-7, VDE 0815, VG 95218, NEK 606 OR as per customer’s specifications.

LV Power & Control Cables

Construction

Al/Bare Cu/Tinned Cu, PVC/XLPE/HR PVC Insulated, Armoured/Unarmoured, LSZH /FRLS/FR/PVC/HR PVC/HDPE Inner & Outer Sheath.

Size

(Power) 1C, 2C, 3C, 4C,- 4 sq mm to 1000 sq mm, 3.5C – 25 sq mm to 630 sq mm or as per client’s requirement. (Control) 1.5sq mm- 2C to 100 Cores & 2.Ssq mm -2C to 100 Cores or as per client’s requirement. IS: 1554 (P-1), IS: 7098 (P-1), !EC: 60502 (P-1), BS: 5467, BS: 6724, BS: 6346, BS: 7889

Building wire

Construction

Bare/Tinned Cu, PVC/HR PVC/FRLS/FR/LSZH/EI-5 Insulated, PVC/HR PVC/LSZH Sheath (for Muth Core).

Voltage Grade

300 / 450 / 600 / 1100 Volts

Size

House Wire — 0.5 sq mm to 6 sq mm, Multi Core — 2C to 24C — 0.5 sq mm to 35sq mm Single Core Flexible — 0.5 sq mm to 630 sq mm, Building Cables — 0.5 sq mm to 6 sq mm and as per client’s requirement

Referred standards

IS:694, BS:6004, BS:6500, BS:7211, IEC-60227-1, 2, 3, 5 CSA-22.2 No.38-05